Robert Foxworth wrote:
> 
> As you see, only pairs 2 and 3 conduct signal.
> Pairs 1 and 4 are electrically idle, but the spec
> says they are all connected. When making cables you
> need to connect them anyway to maintain proper
> wire position.
100baseTX uses one pair of wires for transmission (125Mbaud 4B/5B 
encoding), and a second pair for collision detection and receive. Due to 
the 20% overhead of 4B/5B encoding, 125Mbaud becomes 100Mbit.
100baseT4 uses 3 pairs for transmission (33Mhz per pair) and the fourth 
pair for collision detection. The lower signalling rate makes it 
possible to use Cat3 cabling.
1000baseT uses all 4 pairs for transmitting and receiving (125Mbaud 
PAM-5 encoding). 4x250Mbit = 1Gbit.
With 10baseT and 100baseTX, both pairs are electrically active - the 
balanced twisted pairs allow for detection and correction of errors 
induced in both lines.
- Ian
This archive was generated by hypermail 2.1.3 : Fri Aug 01 2014 - 19:00:57 EDT