Why did you not say you had conduit.

Make a small plug like a Ping Pong ball, tie a fishing line to it, and 120
pounds of air pressure and it should shoot through most conduit unless it has
to many L in it.

Frank

On Friday 16 July 2004 13:43, Doug Koobs wrote:
> I still wonder how, in the general case, to get cord
>
> > through the conduit initially, but since that's not relevant here, it's
> > not too important.
>
> In my electrician days, I usually used two methods, depending on the
> situation. You can use a ShopVac on one end, and a plastic baggie (called
> a "mouse") tied to a pull string on the other end. Then just suck the
> mouse and pull string through. This works best with PVC conduit, since it
> is generally more airtight than the metal varieties.
>
> You can also use a fish tape, like ths:
> http://www.divineimages.com/prod/it32/303/100/FISH/TAPE/ELECTRICIAN/PULL/WI
>RES.htm
>
> Just push the fish tape in one end till it pops out the other end. Not
> near as fun as the ShopVac and mouse :)
>
> Of course, you can always put a pull string in the conduit as you are
> initially installing...
>
> Doug
>
> -----------------------------------------------------------------------
> This list is provided as an unmoderated internet service by Networked
> Knowledge Systems (NKS). Views and opinions expressed in messages
> posted are those of the author and do not necessarily reflect the
> official policy or position of NKS or any of its employees.

-----------------------------------------------------------------------
This list is provided as an unmoderated internet service by Networked
Knowledge Systems (NKS). Views and opinions expressed in messages
posted are those of the author and do not necessarily reflect the
official policy or position of NKS or any of its employees.



This archive was generated by hypermail 2.1.3 : Fri Aug 01 2014 - 20:32:50 EDT